Price Computing ScalePrice Computing SeriesOperation ManualCardinal®CARDINAL SCALE MFG. CO.P.O. Box 151 • Webb City, MO 64870PH: 417-673-4631 • Fax: 4
8Right Side CoverCalibration SwitchCircuit BoardSETUP AND CALIBRATION PROCEDUREThis scale was calibrated at the factory and should not require adjustm
9WEIGHTSETUP AND CALIBRATION PRIOCEDURE (cont.)3a.LoAd = If recalibration is not desired, press 0 (zero) then ENTER and proceed to step five.3b. If r
10SETUP AND CALIBRATION PROCEDURE (cont.)10. tArE= Enter 0, 1, or 2 and press ENTER.0 = Disables keypad tare and enables push button tare.1 = Enables
11SETUP AND CALIBRATION PROCEDURE (cont.)13. bAUd= Enter the value for the baud rate desired and press the ENTER key.12 = 1200 baud 48 = 4800 baud 19
12STORE NAME/IDCharactersNote: All unused locations to the right are ignored.17a. bArC= Enter 1 (Yes) to provide bar code printing, 0 (No) to disable
13SETUP AND CALIBRATION PRIOCEDURE (cont.)18. donE= Indicates that calibration/setup is complete and calibration data will be stored at thistime. Pre
142. Operator keys in one or two digits (00 to 99) representing the price preset number, thenpresses the ENTER key.3. Repeat both steps to recall othe
15ERROR MESSAGESIndicates that the scale has never been setup and calibrated or has beeninterrupted during the setup and calibration sequence.Indicate
16BEFORE YOU CALL FOR SERVICE. . .Customer satisfaction is of utmost importance. Should you experience difficulty with the operation ofthis instrument
17SERIAL DATA OUT AND WEIGH ON DEMAND FUNCTIONThe PC series scale will transmit SMA Level 1 compliant serial weight data when the PRINT key isdepresse
PRECAUTIONSBefore using this instrument, read thismanual and pay special attention to all“WARNING” symbols: IMPORTANT ELECTRIC
18PC SERIES INTERFACE CABLESThe PC series scale can be interfaced to different Detecto printers as well as to a host computer.The following table list
2
UNAM&EDSIGUNEDFACTREDINUSA...UNAM&EDSIGUNEDFACTREDINUSA...
1SPECIFICATIONSPower Requirements: 115 VAC, 50/60 Hz (Optional 230 VAC, 50/60 Hz); powering a 12 VDC,700 mA wall-plug-in power moduleDimensions: Base:
2COMPONENTS AND CONTROLSWeightDisplayUnitPrice$DisplayTotalPrice$DisplayPrinterOutputCableCapacityCommodity TrayNumericKeys (10)WeightDisplayUnitPrice
3COMPONENTS AND CONTROLS (cont.)LeveledNot leveledShipping thumbscrew(located on bottom of scale)REMOVE ALL SHIPPING SCREWSBEFORE USING SCALE, TWOSCRE
4KEY FUNCTIONSThis section describes the use of each of the keys on the Price Computing Scale.The membrane keyboard is not to be operated with pointed
5KEY FUNCTIONS (cont.)Pressing the 250g/ 1/2 key computes price per 250g or 1/2lb depending on the scalemode.NOTE: With the scale mode set for kg oper
6OPERATIONNormal Unit Price1. Place commodity on scale.2. Key in unit price per pound or kilogram.3. Read total weight and total price.4. Remove commo
7OPERATION (cont.)Tare operation for known tare (container) weightNote: Known tare weights must be entered as numbers compatible with the particular s